General information
Catalog number
EKU06403
Size
10x96T
Price
6202.00 €
Detailed information
Verified reactivity
Homo sapiens (Human)
Detection limits
0.312-20 ng/mL
Sensitivity limit
0,128 ng/mL
Samples to be analyzed
Serum, plasma, tissue homogenates and other biological fluids
Assay duration
3 hours
Verified applications
ELISA
Assay class
Sandwich
ELISA detection
Colorimetric
Protein number
P00480
Alternate protein number
Please refer to SwissProt
Gene number
5009
Gene name
Ornithine Carbamoyl Transferase
Alternate gene name
OCTD; OTCase; Ornithine Transcarbamylase; Ornithine Carbamoyltransferase
Estimated production time
7-11 business days
Shipping requirements
Blue ice
Storage recommendation
-20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
Use for
8 months
ELISA's specificity
This assay has high sensitivity and excellent specificity for detection of Ornithine Carbamoyl Transferase (OCT). No significant cross-reactivity or interference between Ornithine Carbamoyl Transferase (OCT) and analogues was observed.
ELISA's cross-reactivity
This assay doesn't seem to cross-react with other species. For more information about cross-reactivity please contact us.
Assay principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Ornithine Carbamoyl Transferase (OCT). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Ornithine Carbamoyl Transferase (OCT). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Ornithine Carbamoyl Transferase (OCT), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Ornithine Carbamoyl Transferase (OCT) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Protocol
Please see ELISA's datasheet, otherwise contact us
Precision of the test
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ornithine Carbamoyl Transferase (OCT) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ornithine Carbamoyl Transferase (OCT) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV
ELISA's stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
QC
The Kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
Research main area
Enzyme & Kinase;Metabolic pathway;
Warnings
The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
Notes
For research use only. Not for diagnostic procedures.
Properties
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.
Test
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
Description
A microtiter plate (spelled Microtiter is a registered trade name in the United States) or microplate or micro well plate or multiwell, is a flat plate with multiple "wells" used as small test tubes. The microplate has become a standard tool in analytical research and clinical diagnostic testing laboratories. A very common usage is in the enzyme-linked immunosorbent assay (ELISA), the basis of most modern medical diagnostic testing in humans and animals. A microplate typically has 6, 24, 96, 384 or 1536 sample wells arranged in a 23 rectangular matrix. Some microplates have even been manufactured with 3456 or 9600 wells, and an "array tape" product has been developed that provides a continuous strip of microplates embossed on a flexible plastic tape.